Identifier
ARES-8588
Version Identified
Workspace ONE UEM 1905+
Symptoms
When uploading a new version of an internal application, if the Retire Previous Version option is selected, the older versions of the app and the new version of the internal app is retired. This behavior can lead to the application being removed from all assigned devices.
For Example: If versions 1.2, and 1.3 of an internal app are in the Workspace ONE Console and version 1.5 is added using the method above, versions 1.2, 1.3, and 1.5 will be set to the Retired state
Workaround
In order to retire previous versions of an internal applications, administrators may do the following:
- Upload the new version of the app without selecting Retire Previous Version
- Save and Assign this new version as required
- Navigate to the Application Details View of the older versions of the app by clicking it from the List View page
- Select More > Retire from the Details View
Fix Version
A patch has been deployed across all SaaS environments on Workspace ONE UEM 1905 to resolve this issue.
Other Languages: 日本語