[Resolved] INTEL-7849: Inaccurate Data due to Events in Pending State

Identifier

INTEL-7849

 

Version Identified

Workspace ONE UEM 9.4+ (On-Premises)

 

Symptoms

Workspace ONE Intelligence custom reports and sync status pages show inaccurate count of devices or apps as compared to the Workspace ONE UEM console due to records stuck in a pending state in the UEM Database’s export queue. This occurs if the ADP_Export SQL Agent job doesn’t execute for a period either due to it being disabled or absent on the active SQL node.

 Intel-7849.png

Note: This only affects On-Premises customers. 

 

Workaround

Workspace ONE UEM 9.4 – 9.6: A one-time script (found here) can be executed on the Workspace ONE UEM database to reset the status of such records, allowing them to be exported successfully. However, if future events/records become in pending state again, this script will need to be run again.

Workspace ONE UEM 9.3 and below: It is recommend to upgrade to the latest version of Workspace ONE UEM.

 

Fix Version

This issue has been resolved in Workspace ONE UEM 1810. 